220V |
Complete scheme for the collection |
Free powerful consumers |
Powerful consumers, such as electric boilers, fireplaces, stoves, refrigerators, irons, kettles and others, can be switched on so that the meter does not take them into account |
Screw |
The method is the easiest. If, for some reason, the meter does not have a cover on the meter terminal block or a seal on it |
Opening of the counter "CO" |
Screws, a seal and a wire are whole. Access to the counter is complete! |
Reactive power generator 1 kW |
The implementation of this scheme will allow you to rewind their indications for induction counters, and with regard to electronic stop the full count of electricity. All this is done without changing the schemes for their inclusion. The main element of the device is a capacitor, which is charged for a quarter of a period of mains voltage by high-frequency pulses (the counter does not react to them), and then it is discharged directly into the network. The discharge energy directly affects the amount of the winding current or the amount of undercount of electricity. Advantages: 1. The device, assembled according to the proposed scheme, simply inserted into the socket, and the counter begins to count in the opposite direction. 2. All wiring remains intact. 3. Earthing is not necessary. Disadvantages: You need some knowledge of electronics and the ability to hold a soldering iron in your hand! Result of work: With the elements indicated on the diagram, the device is designed for a rated voltage of 220 V and the winding power is approximately 2 kW. The use of other elements allows you to increase the power accordingly. |
Reactive power generator 2 kW |
The device is designed to rewind indications of induction electric meters without changing their switching circuits. With regard to electronic and electronic-mechanical counters, the design of which is incapable of counting down the reading, the device allows you to completely stop the account to a power consumption of several kW |
Reed switch |
It is practically impossible to detect it (with the magnet removed), and even if it emerges, any responsibility from the subscriber will be removed by genuine seals of the state verification and the verification protocol of the meter. It is also suitable for a three-phase network |
Garland |
The switching circuit of the counter is changed so that it is not connected to the supply line, but to the fuse blocks |
Garland stop |
To stop any meter, including electronic |
Garland coils |
The more the load, the faster the counter counts in the opposite direction |
Friends |
The method is used, as a rule, in cases when one consumer has on his balance sheet 1-ф. Counter and 3 f. Counter (power), or when neighbors are on friendly terms |
Remote stop and return of the electricity meter |
Remote stop and return of the electric meter (Remote stop and return of the electricity meter) |
Needle |
The induction electric meter can be stopped with a long needle that reaches the disc |
Measuring circuits |
Can stop semi-private (through TT) accounting. |
Artificial zero |
Any counter, including the electronic one, can be stopped without resorting to rephasing the supply conductors. The circuit for turning the meter on remains standard, but using grounding creates an artificial zero, which is used instead of the natural zero wire, and a small damage is introduced in the wiring |
Capacitor |
In this way, we can "save" up to 5% of electricity without consideration. At that without the need of access to the electricity meter. The essence of the method is to create a capacitive load, which reduces the angle between the current and voltage vectors from 90 to 0 degrees. That allows you to reduce the amount of reactive energy! And save on it. The main element of the device is a capacitor, which is charged for a quarter of a period of mains voltage by high-frequency pulses (the counter does not react to them), and then it is discharged directly into the network. In the first quarter of the network voltage period, the energy is consumed from the network, the capacitor C1 is charged, but it is charged via transistor switches A and D which are controlled by high-frequency pulses, that is, the energy for charging is consumed by high frequency pulses. It is known that counters, incl. Electronic, contain an inductive current sensor with a magnetic core having limited frequency conductivity, and induction ones, which contain, besides the magnetic one, also the mechanical part of the measuring system, have a very large negative error when the RF current flows. Remains in the second quarter of the period, discharge the capacitor into the network without any impulses, through the same keys. Similarly, the second half-cycle through the other arm of the keys C and B ... So, for example: They consumed 2 kW, the meter took into account 0.5 W, gave an ideal 2 kW, the meter took into account -2 kW. The result of the period - the induction counter is turned back at a speed of -1.5 kW, and the electronic counter is up to 1.5 kW. The discharge energy directly affects the amount of the winding current or the amount of undercount of electricity. Advantages: 1. The entire wiring system remains untouched. 2. The device assembled according to this scheme is simply inserted into the socket and the mechanical counter starts to rotate in the opposite direction, and the electronic device simply stops. 3. Earthing is not required. Disadvantages: You need some knowledge of electronics using microcontrollers. Result of work: Induction counters reduce their readings by 1-1.5 kW / h, and the electronic stops or underestimates about the same amount of electricity. |
Cremation of the voltage coil |
With the aid of the simplest circuit, which is included in a conventional socket, in induction three-phase counters, the voltage coil of the phase from which the above-mentioned socket is energized is disabling. The process of failure of one counter element takes a maximum of 2 minutes |
Magnet |
The simplest way that anyone can use |
Magnet 2 |
This method has been tested for a single-phase electromechanical counter |
Mechanism |
Violation of accounting, without infringement of authentic seals of state verification |
Incline |
Violation of accounting, without infringement of authentic seals of state verification |
Direct current magnetization |
A significant increase in the negative error in induction electric meters is achieved by passing a direct current through their current coils |
Zero + |
100% guaranteed full stop of the electricity meter of any type (1-ph and 3-phase, induction and electronic, domestic and imported). This method is based on the main principle of accounting for electrical energy in mechanical induction and electronic energy meters, both in single-phase and in three-phase. To implement this scheme, you do not need to interfere with the internal mechanisms of the counters. All seals remain untouched! It is only necessary to have access to the meter itself. This scheme is ideal for residents of multi-storey buildings, and of course it is possible to install in any residential building. In this scheme, implemented a brilliant solution, which was always on the mind, that almost no one even suspected how easily it is executed. Here you will be given not one but five solutions to this idea. Added a method that is almost completely unknown to employees of energy-saving organizations. Some think that this method involves using grounding and dragging the phase through the common wire of the counter. I want to say that this method has nothing to do with it and grounding is not required! Advantages: 1. In order to implement this method, you do not need to have any special knowledge and do not need any additional electronic components. 2. There is an unlimited possibility of consuming electrical energy. 3. This method is the most effective and safe! Therefore, we offer it first in the list. 4. Seals on the counter remain untouched. 5. The possibility of detection is practically zero. 6. The method is practically unknown to the employees of the power supply. Disadvantages: ABSENT! |
Icing |
In the case of installing an electronic-mechanical counter outside the premises, some of its subscribers have adapted to switch off for the whole winter |
Heating |
The device is intended for connection of household consumers and the main electric heaters in an alternating current network. Nominal supply voltage from the network of 220 V, power consumption of about 1 kW. The use of other elements allows the device to be used to power more powerful consumers. This circuit is implemented on the same principle as the winding generator circuit, i.e. These schemes are equivalent, but they are executed in different ways. The operation of the device is based on the fact that the load is not powered directly from the AC mains, but from the capacitor, whose charge corresponds to the sine of the mains voltage, but the charging process itself occurs by high frequency pulses. The current consumed by the device from the electrical network is a high frequency pulse. Electricity meters, including electronic ones, contain an input induction converter that has a low sensitivity to high frequency currents. Therefore, energy consumption in the form of pulses is accounted for by a counter with a large negative error. The discharge energy directly affects the amount of the winding current or the amount of undercount of electricity. Advantages: 1. The device, assembled according to the proposed scheme, is simply inserted into the socket and the load is supplied from it. 2. All wiring remains intact. Earthing is not necessary. The meter takes into account about a quarter of the electricity consumed. 3. Earthing in this implementation scheme is not necessary. Disadvantages: You need some knowledge of electronics, electrical engineering and the ability to hold a soldering iron in your hand! The result of the work: With the elements indicated on the diagram, the device is designed for a rated voltage of 220 V and the power at which the counter underestimates the energy of 2 kW. The use of other elements allows you to change the power accordingly. Our advice is to buy two schemes at once: this! And the winding generator. They are implemented according to different schemes and the principle of work is the same! Therefore, you can then choose the most suitable scheme for you. |
Bypassing two counters |
When the load is switched on, electricity meters will not be counted for consumption. |
Hole |
Up to 100% of consumed electricity is not taken into account (not suitable for electronic electricity meters) |
onmouseover="style.backgroundColor='#F0F0F0'" onmouseout="style.backgroundColor='#FFFFFF'">
Winding counters without grounding |
If it is not possible to use grounding, the counters can still be rewound. For this, there should be a neighbor nearby with whom you are on good terms |
Uncoiling transformer |
If the meter has counted a large amount, then its readings can be reduced by inserting into the socket a conventional step-down transformer equipped with an additional circuit |
Voltage Jumpers |
3-phase meters (up to 100% of electricity is not taken into account) |
Seal of state inspection |
Twisting drums of the counting mechanism - up to 100% of the consumed electricity without taking into account, shunt current coil - you can achieve 100% of the unaccounted for electricity, reed switch and resistance - from 30 to 100% of electricity is not taken into account |
Positron 1 |
The entire wiring system remains intact. The device, assembled according to the following scheme, is simply inserted into the socket and the counter starts to rotate in the opposite direction. Grounding is also not required. |
Positron 2 |
The basis of this method is the ability to use electricity without accounting if the meter is connected incorrectly |
Positron 3 |
Voltage windings in a three-phase active energy meter |
D.C |
A significant increase in the negative error of the induction electric meters can be achieved by passing through their current coils a direct current that will make a magnet from the core of the current coil |
Actuator |
The ability to use almost unlimited number of times, the difficulty of detection, all the seals and the meter itself remain without damage. Suitable for three-phase accounting. |
Bit depth |
In the case of a qualitatively made inscription on the panel, it is very difficult to detect |
Burning the winding of a three-phase meter |
This method allows you to use unconditionally and unlimitedly one phase after a three-phase meter without disassembling the meter, if all the seals are intact, including the introductory switching device, and without cutting the input cable. |
Phase Shift |
To wind the readings of the induction counter, which counted too much, it is possible by switching the capacitor in series with the voltage coil |
Resistance in the voltage winding |
In this method, the value of the voltage U is changed on the voltage winding of the induction counter or the voltage sensor of the electronic counter |
Current transformer plate |
It can be detected by a controller who memorized all the features of known current transformers by heart or goes to check with directories |
Current coil |
Undercounting by 20% for all types of counters |
Brake |
The induction electric meter can be stopped with a thin flat object, playing the role of a brake pad for a disk |
Transformer |
It allows to rewind the induction electric meter and stop the electronic. |
Transformer 2 |
The most common method of unwinding |
Phase ZERO "He's the same way" extender |
Allows you to stop 1-ph. Electric meter of any type |
Physics, 9th grade |
As you know, the electric meter is essentially a wattmeter, from this it is worth applying the knowledge of the 9th grade in physics |
Sly Rectifier |
The rectifier is intended for supplying household consumers that can work both on alternating current and direct current |
Worm |
As a result, the disk rotates as it should, the mechanism has remained unchanged - even an autopsy will not give a result, but the meter counts 2 times less |
Shock therapy |
This method is used for both single-phase and three-phase accounting, but only to counters in which there is no mechanical memory, i.e. to counters with digital indication |
Shunt counter |
This method has been tested for a single-phase meter. The current coil of the counter is shunted, thick wire |
Shunting of current winding |
This method is used for a single-phase counter |
Electronic |
The entire wiring system remains intact. The device, assembled according to the following scheme, is simply inserted into the socket and the counter starts to rotate in the opposite direction. Grounding is also not required. |
"Electronic 2 (electronic plus) |
The device is designed to rewind indications of induction electric meters without changing their switching circuits. With respect to electronic and electronic-mechanical counters, the construction of which is incapable of counting down |
Electronic limiter |
The device is intended for supplying household consumers with alternating current. Rated voltage 220 V, power consumption 1 kW. The use of other elements allows the device to be used to power more powerful consumers |
The new way "Hidden Zero" is my way and scheme |
Self-made way |
Method 1 |
The most oak way. Suitable only for houses of the Czech project |
Method 2 |
Verified method sent |
Method 3 |
Verified method sent |
Method 4 |
Verified method sent |
Method 5 |
Verified method sent |
Method 6 |
Verified method sent |
Method 7 |
Verified method sent |
Method 8 |
Verified method sent |
Method 9 |
Verified method sent |
Method 10 |
Verified method sent |
Method 11 |
Verified method sent |
Method 12 |
Verified method sent |
Method Battery |
PARALLEL VOLTAGE RESONANCE, in which the power drawn from the outlet will tend to infinity, and the counter reading will then go to ZERO |
What to do if the counter is counted slowly |
When, after opening the counter began to be considered incorrect, with the help of a stopwatch, any controller can detect this |
Principle of operation |
To calculate the electrical energy consumed for a certain period of time, it is necessary to integrate instantaneous values of active power |
How to rewind (theory) |
Electricity is now expensive - it's not a secret. But the fee for all this economy can be significantly reduced. Here the main sense of proportion. If it turns out that you have not consumed a kilowatt for half a year, wait for the energy inspection with all the |
Other schemes (3 pcs) |
Ways of winding and stopping counters |
Comments
When commenting on, remember that the content and tone of your message can hurt the feelings of real people, show respect and tolerance to your interlocutors even if you do not share their opinion, your behavior in the conditions of freedom of expression and anonymity provided by the Internet, changes Not only virtual, but also the real world. All comments are hidden from the index, spam is controlled.