Catalog and description of electricity meters.



Here are the data of some (by far not all) counters.
Ways to change the readings are suitable for missing counters!

СО-ЭЭ6706

СО-ЭЭ6706

Round enclosure
Measurement and recording of electrical energy in single-phase alternating current networks

  • Accuracy class: 2.0
  • Rated-maximum current, A: 5-20; 10-40
  • Rated frequency 50 Hz
  • Full and active power consumed by a voltage circuit of 5.5VA and 1.3W respectively
  • The total power consumed by the current circuit is not more than 0.35 V.
  • Operating temperature range, 0С: -20 to +60
  • Verification interval: 16 years
  • Average service life: not less than 32 years

СО-ЭЭ6705

СО-ЭЭ6705

 

Rectangular enclosure
Measurement and recording of electrical energy in single-phase alternating current networks

  • Accuracy class: 2.0
  • Rated-maximum current, A: 5-20; 10-40
  • Rated frequency 50 Hz
  • Full and active power consumed by a voltage circuit of 5.5VA and 1.3W respectively
  • The total power consumed by the current circuit is not more than 0.35 V.
  • Operating temperature range, 0С: -20 to +60
  • Verification interval: 16 years
  • Average service life: not less than 32 years  

CE2726

CE2726

 

Measurement and accounting of electrical energy and capacity at 4 tariffs

  • Accuracy class: 1.0
  • Rated-maximum current, A: 5-50
  • Rated frequency 50 Hz
  • Full and active power consumed by a voltage circuit of 5.0VA and 2.0W respectively
  • The total power consumed by the current circuit is not more than 0.5 V.
  • Operating temperature range, 0С: -25 to +55
  • Verification interval: 16 years
  • Average service life: not less than 30 years
  • Telemetry output
  • There is a modification with an integrated power-line modem

The meter provides commercial accounting in systems (AMRMS)

CE-2705

CE-2705
  •        Rated voltage of controlled network 220 V
  • -          Range of voltage variation of the monitored network (187 ... 242) V
  • -          Rated load current 5 A
  • -          Maximum load current 50 A
  • -          Minimum load current 0,25 A
  • -          Short-time overcurrent 150 A
  • -          Rated frequency of controlled network 50 Hz
  • -          Range of frequency variation of the monitored network (47.5 ... 52.5) ​​Hz
  • -          Total power consumed by the current circuit is not more than 0.05 VA
  • -          Active and total power consumed in the voltage circuit is not more than 2.5 VA
  • -          Accuracy class in the range of loads 1 ... 1000% nom. Current 1,0; 2.0
  • -          The transmission ratio of the main transmitter is 16000 imp / kWh
  • -          Intertesting interval 16 years
  • -          Average service life 30 years

SOLO

SOLO

 

Measurement and recording of electricity in domestic, small-engine and industrial sectors

  • Accuracy class: 1.0; 2.0
  • Rated-maximum current, A: 5-60; 10-80; 10-100
  • Rated frequency 50 Hz
  • The total and active power consumed by a voltage circuit of 8.0 VA and 2.0 W respectively
  • The total power consumed by the current circuit is not more than 0.5 V.
  • Operating temperature range, 0С: -25 to +55
  • Verification interval: 16 years
  • Average service life: not less than 30 years
  • Telemetry output

The counter provides commercial accounting in the systems

Mercury-200

Mercury-200

Measurement and recording of electricity in domestic, small-engine and industrial sectors

  • Accuracy class: 2.0
  • Rated-maximum current, A: 5-50
  • Rated frequency 50 Hz
  • Full and active power consumed by a voltage circuit of 10 VA and 2.0 W respectively
  • The total power consumed by the current circuit is not more than 2.5 V.
  • Operating temperature range, 0С: -20 to +55
  • Calibration interval: 8 or 16 years (see modification)
  • Average service life: not less than 30 years
  • Number of tariff zones: 1-4
  • Multi-tariff meters have a serial built-in CAN interface that provides information exchange with a computer
  • The possibility of fastening both in the traditional way, and on the DIN-rail.

CA4-I672M, CA4U-I672M

CA4-I672M, CA4U-I672M

 

Three-phase induction
Active energy of direct and transformer inclusion

Measuring and recording of active energy in three-phase three- and four-wire AC networks

  • Accuracy class: 2.0
  • Rated frequency 50 Hz
  • Total power consumed by the voltage circuit from 5.0 to 6.0VA, active from 1.5 to 2.0W (depending on the type of meter)
  • The total power consumed by the current circuit is from 0.6 to 1.0VA, and with a maximum current of more than 30A, not more than 2.5VA
  • Operating temperature range, 0С: 0 to +40
  • Calibration interval: 6 years
  • Average service life: not less than 32 years
  • Full nomenclature series for rated-maximum current, voltage and wiring diagrams

CA4-I678, CA4U-I678

CA4-I678, CA4U-I678

 

Three-phase induction
Active energy of direct and transformer inclusion

Measuring and recording of active energy in three-phase three- and four-wire AC networks

  • Accuracy class: 2.0
  • Rated frequency 50 Hz
  • Total power consumed by the voltage circuit from 5.0 to 6.0VA, active from 1.5 to 2.0W (depending on the type of meter)
  • The total power consumed by the current circuit is from 0.6 to 1.0VA, and with a maximum current of more than 30A, not more than 2.5VA
  • Operating temperature range, 0С: 0 to +40
  • Calibration interval: 6 years
  • Average service life: not less than 32 years
  • Full nomenclature series for rated-maximum current, voltage and wiring diagrams

СА3-И670М, СА3У-И670М

СА3-И670М, СА3У-И670М

 

Three-phase induction
Active energy of direct and transformer inclusion

Measuring and recording of active energy in three-phase three- and four-wire AC networks

  • Accuracy class: 2.0
  • Rated frequency 50 Hz
  • Total power consumed by the voltage circuit from 5.0 to 6.0VA, active from 1.5 to 2.0W (depending on the type of meter)
  • The total power consumed by the current circuit is from 0.6 to 1.0VA, and with a maximum current of more than 30A, not more than 2.5VA
  • Operating temperature range, 0С: 0 to +40
  • Calibration interval: 6 years
  • Average service life: not less than 32 years
  • Full nomenclature series for rated-maximum current, voltage and wiring diagrams

CP4-I673M, CP4U-I673M

CP4-I673M, CP4U-I673M

 

Reactive energy of direct and transformer inclusion

Measurement and accounting of reactive energy in three-phase three- and four-wire AC networks

  • Accuracy class: 2.0 (for direct inclusion counters 3.0)
  • Rated frequency 50 Hz
  • Total power consumed by the voltage circuit from 5.0 to 6.0VA, active from 1.5 to 2.0W (depending on the type of meter)
  • The total power consumed by the current circuit is from 0.6 to 1.0VA, and with a maximum current of more than 30A, not more than 2.5VA
  • Operating temperature range, 0С: 0 to +40
  • Calibration interval: 6 years
  • Average service life: not less than 32 years
  • Full nomenclature series for rated-maximum current, voltage and wiring diagrams

CE2727

CE2727

 

Three-phase electronic active energy direct and transformer inclusion.

Measuring and recording of active energy in three-phase three- and four-wire AC networks at 8 tariffs in 8 time zones

  • Accuracy class: 1.0
  • Rated voltage, V: 3 x 57.7; 3 x 100; 3 x 380; 3 x 220/380
  • Rated-maximum current, A: 1-2; 5-10; 5-50; 10-100
  • Rated frequency 50 Hz
  • Full and active power consumed by a voltage circuit of 5.0VA and 2.0W respectively
  • The total power consumed by the current circuit is not more than 0.2 V.
  • Operating temperature range, 0С: -25 to +55
  • Intertesting interval 8 years
  • Average service life of at least 30 years
  • Interface: RS232; RS485; Telemetering channel
  • Intertesting interval 8 years

The modification with built-in electric power modem allows to use the meter in the system (ASKUE) with transmission of data on the power network 0.4 kV

F669

F669

 

Three-phase multifunction active-reactive

Measurement of active and reactive energy and power in two directions at 4 tariffs in 5 time zones

  • Accuracy class: 0.5S; 1.0
  • Rated voltage depending on wiring diagram
  • Rated-maximum current, A: 1-1,25; 5-6.25
  • Rated frequency 50 Hz
  • Full and active power consumed by a voltage circuit of 4.0 VA and 2.0 W respectively
  • The total power consumed by the current circuit is not more than 0.3 V.
  • Operating temperature range, 0С: -20 to +55
  • Intertesting interval 8 years
  • Average service life of at least 20 years
  • Interfaces: "current loop" type, telemetry output, optical port, RS232; RS485

The counter for its functionality is not inferior to the best foreign samples

Mercury 230

Mercury 230

Three-phase electronic multifunctional active and active-reactive energy

Measurement and recording of active and active-reactive energy in the forward direction in three-phase alternating current networks with a nominal frequency of 50 Hz.

  • The accuracy class of active energy: 0.5; 1.0
    Active-reactive energy: 0.5 (1.0); 1.0 (2.0)
  • Nominal-maximum current, A; 5-50; 10-100; 5-7.5
  • Full and active power consumed by a voltage circuit of 7.5VA and 0.5W respectively
  • The total power consumed by the current circuit is 0.1 V.A
  • Number of tariff zones: 1- 4
  • Range of operating temperatures C: -20 to +55
  • Calibration interval - 8 years
  • Average service life of at least 30 years
  • Counters have a serial interface CAN, providing information exchange with the computer
  • Counters can be used, both autonomously and in AMR systems

СО-50

СО-505

Purpose : The single-phase electricity meter SO-505 is designed for the recording of active electricity in everyday life, public and industrial premises.

Principle of operation: The operating principle of the CO-505 electric meter is based on the use of an induction measuring system.

Variants of execution : The electric meter СО-505 has a variant of execution СО-505Т with telemetric output. The reading telemetry device allows the use of the meter in an automated system for monitoring and recording electricity.
Options for the execution of the casing, the presence of a retarder stop are determined by the customer.

ESR-5

ESR-5

 

Purpose : Electricity meters SOE-5 are designed to measure active electrical energy in two-wire AC circuits with a voltage of 220V, frequency of 50Hz.

They are produced in three versions: one-tariff, two-tariff with an external tariff switch and a lot of tariffs with an internal tariffifier for work in automated systems for monitoring and accounting for energy consumption.

Counters with an internal tariff meter have a digital interface RS-232 or RS-485. Using the digital interface, the time of the tariffs is set, the accuracy of the clock is corrected, and the data is read. For storing information in the meters there is a non-volatile EEPROM memory. The memory registers store data for each tariff.

The meters have a telemetric output galvanically isolated from other circuits.

ESR-52

ESR-52

 

Electricity meters SOE-52 are designed to account for electricity consumption in two-wire electric circuits in closed rooms. Can be operated autonomously and as part of an automated system for monitoring and accounting of electricity (AMR) using pulse output.

The meters correspond to GOST 30207-94 (IEC 1036-90) and are registered in the State Register of Measuring Instruments No. 17301-02.

Certificate No. РОСС RU.ME65.B00556

Pluses:

-The presence of LED indicator meter.

-Using SMD-mounting

-There is a telemetry output

CA4U-510, CA4-514, CA4-518

CA4U-510, CA4-514, CA4-518

 

THREE PHASE INDUCTION ELECTRICITY COUNTERS

 

Purpose : Designed for recording active electricity in three-phase four-wire AC networks in industrial plants and household consumers.

Variants of execution : СА4У-510Т, СА4-514Т, СА4-518Т have the built-in photoelectronic adapter with telemetric output for work in the automated systems of the control and the account of power consumption.
At the request of the customer, the counters are equipped with a stop-back stopper that does not allow theft of electricity.
Electricity meters are made of non-combustible materials.

SPECIFICATIONS

 

СА4У-510

 

CA4-514

 

CA4-518


Accuracy class

 

2.0

 

2.0

 

2.0


Method of inclusion

 

Transformer

 

straight

 

straight


Rated voltage, V

 

3х220 / 380

 

3х220 / 380

 

3х220 / 380


Network frequency, Hz

 

50

 

50

 

50


Rated current, A

 

3х5

 

3х10

 

3х20 (3х10)


Maximum current, A

 

3x6.25

 

3х40

 

3х80


Maximum current,% I nom

 

125

 

400

 

400 (800)


Sensitivity threshold, A

 

0.025

 

0.05

 

0.1 (0.05)


Gear ratio, rev / kWh

 

600

 

125

 

60


Number of telemetric output pulses, for execution of "T" imp / kWh

 

600

 

125

 

60

TE560

TE560

 

THREE-PHASE MICROPROCESSOR ELECTRICITY COUNTERS


 

Purpose : Electric meters of the STE560 series are designed to account for active and reactive electrical energy in three- and four-wire three-phase AC networks in industrial plants and household consumers, as well as for work in automated systems for monitoring and accounting for energy consumption. The counters are built on a digital signal processor DSP and are regulated by special programs.

For storing information in the meters there is a non-volatile EEPROM memory. Data registers store data for each tariff.

The meters have a telemetric output, galvanically isolated from other circuits.

To display information, a liquid crystal indicator is used, which is stable at low temperatures.

The counters have a digital interface for the IRPS (current loop). With the digital interface, you can adjust, set the time of the tariff action, adjust the hours and, if necessary, read the meter reading using a computer.

SPECIFICATIONS


Accuracy class:

- for active energy

 

1.0

- by reactive energy

 

2.0


Rated voltage, V

 

3х220 / 380; 3х57,7 / 100; 3х100


Rated current, A

 

5; 10


Maximum current, A

 

7.5; 40; 80


Sensitivity:

- for active energy,% Iн

 

0.25

- for reactive energy,% Iн

 

0.4


Counter constant, imp / kWh

 

1000, 5000


Operating temperature, оС

 

-20 to +55


Average service life, years

 

thirty


Mean time between failures, h

 

100,000


Inter-verification interval, years

 

10


Overall dimensions, mm

 

317 (283) х174х75


Weight, no more than kg

 

1.65

CТС5605, СТС5602

CТС5605, СТС5602

SERIES OF METERS OF THREE-PHASE MICROPROCESSOR COMBINED


 

Purpose : Counters of the series STS5605, STS5602 are three-phase, multi-tariff, electronic, digital, combined devices that combine a multifunctional microprocessor counter and a meter of electrical energy quality indicators. The counters of the STS5605 series of transformer switching are designed for measuring active and reactive power at industrial enterprises and energy facilities. They are used in AMR systems to transmit measured values ​​to the control center for control, accounting and distribution of electrical energy.

 

STK-3

 

STK-3

 

Designed for measuring active and reactive energy in single- and three-phase circuits of three- and four-wire AC circuits, with the possibility of accounting in two directions, with direct or transformer inclusion, autonomously or as part of automated systems for monitoring and recording electricity (ASKUE).

Accounting for electrical energy at energy facilities, industrial plants, in the municipal and domestic sector in conditions of applying differentiated in time tariffs for electricity. Meters can be used in technical or commercial metering systems.

 

Frequency of the measuring network, Hz

50

Sensitivity threshold, mA

From 4

Total power consumption of the parallel circuit, V · A

Up to 3,6

Total power consumption of the series circuit, V · A

Up to 0,3

Pulse telemetry output, imp / kVar / hr

From 1000 to 100000

Number of telemetric outputs

1,2,4

Weight, not more than, kg

2.8

The load graph for each quadrant, the number of accounting points

2160

Digital interface

RS 485

Self-diagnosis system

there is

Overall dimensions, "Energy 8", "STK3-" mm

330x170x70

Overall dimensions, СТК1-10

200х130х80

Integration period

1,3,5,10,30,60

Number of Seasons

Up to 12

Number of time zones for each season

6th

Rated voltage U, V

57.7, 100, 220, 380

Rated current (maximum), A

1 (1.5), 5 (7.5),
10 (40), 40 (100)

Number of Switched Outputs

Up to 4

RS 485 data transfer rate

Up to 19200 baud

Intervalue interval

6 years

Relative air humidity at 30 ° С

Up to 90%

Atmosphere pressure

From 70 to 106.7 kPa

A100

A100

 

Appointment

The meter A100 is designed for the calculation of active energy in single-phase AC circuits in single- and multi-tariff mode, as well as for use in automated systems for monitoring and accounting of electricity (AMRMS). The A100 counter distinguishes performance, resistance to temperature changes, high level of information protection, insensitivity to a constant component and small dimensions.

Functionality

  • The A100 counter allows:
  • Carry out both one-and two-tariff electricity accounting. Switching of tariffs is carried out from an external tariff-maker.
  • Register and store in memory the data confirming the reliability of the information, such as:
    • Total active energy in the opposite direction.
    • Direct indication of the energy flow in the reverse direction on the LCD.
    • Number of power outages.
    • Total operating time of the meter.
    • Operating time after last power-up.
    • Time of the counter in the absence of current.
    • Number of restarted microprocessor.
    • Number of cases of reversal of active energy.
  • Transfer data via infrared (IrDA) or pulse output (RJ11).
  • Store the data when the power is turned off in non-volatile EEPROM memory.

A1000

A1000

Appointment

The А1000 meters are designed to account for active, reactive energy and power measurement in one or two directions in three-phase alternating current circuits, both in single and multi-tariff mode.

Functionality

The counter A1000 allows:

  • Carry out both single and multi-tariff electricity accounting (up to 4 tariffs). Switching of tariffs is carried out from an external tariff-maker.
  • Perform 2 measurements in multi-tariff mode:
    • + P - active consumed energy;
    • + P, -P - active consumed and released energy;
    • + P, + Q - active and reactive energy consumed;
    • + Q, -Q - reactive consumed and released energy;
    • P = | P1 | + | P2 | + | P3 | - active energy modulo;
    • P = | P1 | + | P2 | + | P3 |, + Q - active modulo and reactive consumed energy;
  • Record the maximum power.
  • Register energy when the specified threshold of load power is exceeded.
  • Record the absence of voltage in one or two phases.
  • Measure and display the voltage, current, active, reactive and full power of the network in phase.

ALPHA Plus (A2)

ALPHA Plus (A2)

Appointment

Multifunctional microprocessor three-phase electricity meters ALPHA Plus (A2) is designed for the calculation of active and reactive energy and power in 3-phase AC circuits, control of power quality parameters, as well as for operation in the ASKUE.

Functionality

  • Measurement of active and reactive energies and powers in two directions.
  • Accounting for consumed and issued energy in the multi-tariff regime.
  • Measurement of the maximum load power at the calculated time interval, fixing the date and time of the maximum active and reactive power for each tariff zone.
  • Record and store in the memory of the load schedule data counter.
  • Automatic load monitoring with the possibility of its shutdown or signaling.
  • Transmission of measurement results via digital and impulse communication interfaces (up to two groups of galvanically isolated relays).

Power parameters

The ALPHA Plus counter measures, calculates and displays up to 46 values ​​relating to the parameters of electricity. These include:

  • Current and voltage phases.
  • Active, reactive and full power of the network.
  • Active, reactive and full power phases.
  • The power factor of the network and each phase.
  • Phase angles of voltage and current vectors.
  • The value of the second harmonic in terms of voltage phases.
  • The value of the second harmonic in terms of current phases.
  • The distortion factor of the sinusoidal voltage and current.
  • Network frequency.

Delta

Delta

Appointment

The Delta meter is designed to account for active or active-reactive energy in three- and single-phase alternating current circuits, both in single- and multi-tariff mode, as well as for use in automated systems for monitoring and accounting for electricity (ASKUE).

Functionality

  • Measurement of active or active-reactive energy.
  • Both single and multi-tariff electricity accounting.
  • Installation on DIN-rail or panel.
  • Pulse outputs for operation in the ASKUE.

ST-ER01 (SET)

ST-ER01 (SET)

  • Accuracy class: 1.5
  • Rated-maximum current, A: 5; 7.5
  • Rated frequency 50 Hz
  • Voltage 3х57.7 / 100
  • Total power consumed by the voltage circuit 1VA
  • Operating temperature range, 0С: -25 to +55
  • Calibration interval: 6 years

ST-ER02 (SET)

  • Accuracy class: 1.5
  • Rated-maximum current, A: 5; 50
  • Rated frequency 50 Hz
  • Voltage 3х380 / 220
  • The total power consumed by the 4.5V circuit
  • Operating temperature range, 0С: -25 to +55
  • Calibration interval: 6 years

ST-EA03 (SET)

  • Accuracy class: 1
  • Rated-maximum current, A: 5; 7.5
  • Rated frequency 50 Hz
  • Voltage 3х100
  • Total power consumed by the voltage circuit 1VA
  • Operating temperature range, 0С: -10 to +55
  • Calibration interval: 6 years

ST-EA05 (SET)

  • Accuracy class: 1
  • Rated-maximum current, A: 5; 7.5
  • Rated frequency 50 Hz
  • Voltage 3х100
  • The total power consumed by the voltage circuit is 1VA
  • Operating temperature range, 0С: -10 to +55
  • Calibration interval: 6 years

CO-EA05

CO-EA05

  • Accuracy class: 1.0
  • Rated-maximum current, A: 10; 50
  • Rated frequency 50 Hz
  • Full and active power consumed by a voltage circuit of 5.5VA and 1.3W respectively
  • Operating temperature range, 0С: -35 to +55
  • Calibration interval: 6 years