| CO-EE6706
Housing Round
Measurement and recording of electrical energy in single-phase AC networks - Accuracy class: 2.0
- nominal-maximum current, A: 5-20; 10-40
- nominal frequency of 50 Hz
- full and active power consumed by the voltage VA 5.5 and 1.3 W, respectively
- the total power consumed by the current not more than 0.35 VA
- operating temperature range, 0C from -20 to +60
- Calibration interval: 16 years
- Average life: not less than 32 years
|
| CO-EE6705
A rectangular enclosure
Measurement and recording of electrical energy in single-phase AC networks - Accuracy class: 2.0
- nominal-maximum current, A: 5-20; 10-40
- nominal frequency of 50 Hz
- full and active power consumed by the voltage VA 5.5 and 1.3 W, respectively
- the total power consumed by the current not more than 0.35 VA
- operating temperature range, 0C from -20 to +60
- Calibration interval: 16 years
- Average life: not less than 32 years
|
| TSE2726
Measurement and recording of electrical energy and power to 4 tariffs - Accuracy class: 1.0
- nominal-maximum current, A: 5-50
- nominal frequency of 50 Hz
- full and active power consumed by the voltage VA 5.0 and 2.0 W, respectively
- the total power consumed by current less than 0.5 VA
- operating temperature range, 0C from -25 to +55
- Calibration interval: 16 years
- Average life: at least 30 years
- telemetry output
- a modification of the electric power with built-in modem
The counter provides commercial accounting systems (AMR) |
| COE-2705 -
220 В rated voltage of 220 V controlled
- -
(187…242) В range of the voltage-controlled network (187 ... 242) In
- -
5 А rated load current 5 A
- -
50 А the maximum load current of 50 A
- -
0,25 А minimum load current of 0.25 A
- -
150 А short-term over-current 150 A
- -
50 Гц nominal frequency of 50 Hz controlled
- -
(47,5…52,5) Гц frequency range of the controlled network (47.5 ... 52.5) Hz
- -
не более 0,05 ВА the total power consumed by the circuit current is not more than 0.05 VA
- -
не более 2,5 ВА active and total power consumed in the circuit voltage is not more than 2.5 VA
- -
Class of accuracy in the load range 1 ... 1000% of nominal. 1,0; 2,0 current 1.0, 2.0
- -
16000 имп./кВт·ч transfer efficiency of the main transmitter 16 000 Imp. / kWh
- -
16 лет Calibration interval of 16 years
- -
30 лет average lifespan of 30 years
|
|
SOLO
Measurement and recording of electricity to residential, and industrial sectors melkomotornom - Accuracy class: 1.0, 2.0
- nominal-maximum current, A: 5-60; 10-80; 10-100
- nominal frequency of 50 Hz
- full and active power consumed by the voltage VA 8.0 and 2.0 W, respectively
- the total power consumed by current less than 0.5 VA
- operating temperature range, 0C from -25 to +55
- Calibration interval: 16 years
- Average life: at least 30 years
- telemetry output
The counter provides commercial accounting systems |
| Mercury-200
Measurement and recording of electricity to residential, and industrial sectors melkomotornom - Accuracy class: 2.0
- nominal-maximum current, A: 5-50
- nominal frequency of 50 Hz
- full and active power consumed by the voltage 10V.A and 2.0 W, respectively
- the total power consumed by current less than 2.5 VA
- operating temperature range, 0C from -20 to +55
- Calibration interval: 8 or 16 years (sm.modifikatsii)
- Average life: at least 30 years
- number of tariff bands: 1-4
- multirate meters have built-in serial CAN, which provides communication with the computer
- opportunity to mount a traditional way, and DIN-rail.
|
| CA4-I672M, I672M-SA4U
Three-phase Induction
Direct and active power transformer connection
Measurement and registration of active energy in three-phase three-and four-wire AC circuits - Accuracy class: 2.0
- nominal frequency of 50 Hz
- the total power consumed by the voltage from 5.0 to 6.0 VA, active from 1.5 to 2.0 watts (depending on the type of counter)
- the total power consumed by the current from 0.6 to 1.0 VA, and with a maximum current of 30A is not more than 2.5 VA
- temperature range 0 C: 0 to 40
- Calibration interval: 6 years
- Average life: not less than 32 years
- a complete product range for the maximum-rated current, voltage, and wiring diagrams
|
| CA4-I678, I678-SA4U
Three-phase Induction
Direct and active power transformer connection
Measurement and registration of active energy in three-phase three-and four-wire AC circuits - Accuracy class: 2.0
- nominal frequency of 50 Hz
- the total power consumed by the voltage from 5.0 to 6.0 VA, active from 1.5 to 2.0 watts (depending on the type of counter)
- the total power consumed by the current from 0.6 to 1.0 VA, and with a maximum current of 30A is not more than 2.5 VA
- temperature range 0 C: 0 to 40
- Calibration interval: 6 years
- Average life: not less than 32 years
- a complete product range for the maximum-rated current, voltage, and wiring diagrams
|
| CA3-I670M, I670M-SA3U
Three-phase Induction
Direct and active power transformer connection
Measurement and registration of active energy in three-phase three-and four-wire AC circuits - Accuracy class: 2.0
- nominal frequency of 50 Hz
- the total power consumed by the voltage from 5.0 to 6.0 VA, active from 1.5 to 2.0 watts (depending on the type of counter)
- the total power consumed by the current from 0.6 to 1.0 VA, and with a maximum current of 30A is not more than 2.5 VA
- temperature range 0 C: 0 to 40
- Calibration interval: 6 years
- Average life: not less than 32 years
- a complete product range for the maximum-rated current, voltage, and wiring diagrams
|
| CP4-I673M, I673M-SR4U
Direct and reactive power transformer connection
Measure and record the reactive power in three-phase three-and four-wire AC circuits - Accuracy class: 2.0 (for direct connection counter 3.0)
- nominal frequency of 50 Hz
- the total power consumed by the voltage from 5.0 to 6.0 VA, active from 1.5 to 2.0 W (depending on meter type)
- the total power consumed by the current from 0.6 to 1.0 VA, and with a maximum current of 30A is not more than 2.5 VA
- temperature range 0 C: 0 to 40
- Calibration interval: 6 years
- Average life: not less than 32 years
- a complete product range for the maximum-rated current, voltage and connections Scheme
|
| TSE2727
Three-phase electronic active energy of direct and transformer connection.
Measurement and registration of active energy in three-phase three-and four-wire AC circuits with 8 rates at 8 time zones - Accuracy class: 1.0
- Rated voltage, V: 3 x 57,7; 3 x 100 3 x 380 3 x 220/380
- nominal-maximum current, A: 1-2; 5-10; 5-50; 10-100
- nominal frequency of 50 Hz
- full and active power consumed by the voltage VA 5.0 and 2.0 W, respectively
- the total power consumed by the current does not exceed 0.2 VA
- operating temperature range, 0C from -25 to +55
- Calibration interval for 8 years
- average life of at least 30 years
- Interface: RS232; RS485; telemetry channel
- Calibration interval for 8 years
Availability of electric power versions with built-in modem allows you to use a counter in the system (AMR) with data transmission on power line 0.4 Ap |
| F669
Three-phase multi-function active-reactive
Measurement of active and reactive energy and power in two directions at four rates in the five time zones - Accuracy class: 0.5S; 1.0
- rated voltage, depending on the wiring diagram
- nominal-maximum current, A: 1-1,25; 5-6,25
- nominal frequency of 50 Hz
- full and active power consumed by the voltage VA 4.0 and 2.0 W, respectively
- the total power consumed by current less than 0.3 VA
- operating temperature range, 0C from -20 to +55
- Calibration interval for 8 years
- average life of at least 20 years
- interfaces such as "current loop", the remote output optical port, RS232; RS485
The counter on the functionalities to the best foreign samples |
| Mercury 230
Three-phase electronic multi-function active-active and reactive energy
Measurement and registration of active and active-reactive power forward in the three-phase AC networks 50Hz nominal frequency. - klacs accurate active energy: 0.5, 1.0
active-reactive power: 0.5 (1.0) 1.0 (2.0) - nominal-maximum current, A, 5-50, 10-100, 5-7.5
- full and active power consumed by the voltage VA 7.5 and 0.5 W, respectively
- the total power consumed by the current 0.1 VA
- number of tariff zones: 1 - 4
- Operating Temperature Range C: -20 to +55
- Verification interval - 8 years
- average life of at least 30 years
- counters have a serial interface CAN, which provides communication with a computer
- counters can be used both independently and in AMR systems
|
|
SB-505
Purpose: Single-phase electricity meter SB-505 is designed to account for the active energy in the home, public and industrial buildings. Principle: The principle of operation of the electricity of the SB-505 is based on the induction of the measuring system. Options: Electricity SB-505 has an embodiment of the SB-505T with telemetric output. Reader telemetry device allows you to use a counter in the automated system control and metering of electricity.
Versions of the housing, the availability of reverse stopper determined by the customer.
|
|
Purpose: Electricity ESR-5 are designed to measure active power in the two-wire AC circuits 220V, 50Hz. Available in three versions: one tariff, with an external switch dvuhtarifnye rate tariff and a lot of internal rater to work in automated control systems and metering. Counters with internal rater have a digital RS-232 or RS-485. With the help of a digital interface is the time setting of tariffs, the adjustment accuracy of hours reading the data. To store the information in the counters provided for non-volatile memory EEPROM. The registers in the memory stores data for each tariff. Counters have a telemetry output is galvanically isolated from other circuits.
|
|
Electricity ESR-52 are designed to account for electricity consumption in the two-wire circuit of electric current in enclosed spaces. Can be operated autonomously and as part of an automated system control and energy metering (AMR) using a pulsed output.
Meters correspond to GOST 30207-94 (IEC 1036-90) and registered in the State Register of measuring instruments № 17301-02.
Certificate № ROSS RU.ME65.B00556
Advantages:
The presence of the LED meter.
-The use of SMD-mounting
The presence of telemetry output
|
|
SA4U-510-514 CA4, CA4-518
THREE-PHASE INDUCTION ELECTRICITY METERS
Purpose: Designed to accommodate the active power in three-phase four-wire AC circuits in industrial enterprises and residential customers. Options: SA4U-510T, 514T, CA4, CA4-518T has a built-photoelectron adapter with telemetric output for use in automated control systems and metering.
At the request of the customer to set the counters stop reverse that prevents theft of electricity.
Electricity made of noncombustible materials.
SPECIFICATIONS |
| SA4U-510 | | CA4-514 | | CA4-518 |
| Class of accuracy |
| 2.0 | | 2.0 | | 2.0 |
| Way to incorporate |
| Transformer | | direct | | direct |
| Rated voltage, V |
| 3h220/380 | | 3h220/380 | | 3h220/380 |
| Frequency, Hz |
| 50 | | 50 | | 50 |
| Rated current, A | | 3x5 | | 3x10 | | 3h20 (3x10) |
| Maximum current, A |
| 3x6, 25 | | 3h40 | | 3h80 |
| The maximum current,% I rated |
| 125 | | 400 | | 400 (800) |
| The threshold of sensitivity, A |
| 0.025 | | 0.05 | | 0,1 (0,05) |
| The gear ratio, r / kWh |
| 600 | | 125 | | 60 |
| The number of pulses telemetry outputs for the performance of the "T" imp / kWh | | 600 | | 125 | | 60 |
|
|
MICROPROCESSOR PHASE ELECTRICITY METERS
Purpose: Electricity STE560 series are designed for active and reactive power in three-and four-wire three-phase AC networks in industrial enterprises and residential customers, as well as to work in automated control systems and metering. Counters based on digital signal processor DSP and regulated by means of special programs. To store the information in the counters provided for non-volatile memory EEPROM. The registers in payamyati data is stored on each tariff. Counters have a telemetry output is galvanically isolated from other circuits. To use the liquid crystal display indicator, steadily working at low temperatures. Counters have a digital interface IRPS (current loop). With the help of a digital interface is adjustable to set the time of the tariff adjustment of hours and if necessary, Meter Reading through your computer.
SPECIFICATIONS
| Class of accuracy: | - Active energy | | 1.0 | - For reactive energy | | 2.0 |
| Rated voltage, V | | 3h220/380, 3h57, 7/100, 3x100 |
| Rated current, A | | 5, 10 |
| Maximum current, A | | 7.5, 40, 80 |
| Sensitivity: | - Active energy,% IN | |
0.25 | - For reactive energy,% IN | | 0.4 |
| Real-time counter, pulse / kWh | | 1000, 5000 |
| Operating temperature, ° C | | -20 to +55 |
| Average life, years | | 30 |
| Mean time between failures, h | | 100 000 |
| Mezhproverochny interval, years | | 10 |
| Overall dimensions, mm | | 317 (283) h174h75 |
| Weight, not more than kg | | 1.65 |
|
|
SERIES MICROPROCESSOR METERS COMBINED three-phase
Purpose: Counters series STS5605, STS5602 - three-phase, multirate, electronic, digital, kombirovannye devices that combine multi-function microprocessor-based meter and measuring quality elektroznergii. Counters STS5605 series transformer connection are designed to measure active and reactive power in industrial plants and power plants. Systems used in AMR for transmission of measured values in the control room monitoring, recording and distribution of electric energy.
|
|
| STC-3
Designed to measure active and reactive power in single-and three-phase circuits of three-and four-wire AC, with the possibility of accounting for the two directions, with direct or transformer switching, independently or as part of the automated systems of control and energy metering (AMR).
Accounting for electricity in the power of property, industrial enterprises in the domestic sector in terms of time-differentiated electricity tariffs. Counters can be used in AMR technical or commercial account.
|
Measuring network frequency in Hz |
| The sensitivity threshold, mA |
| Total power consumption of the circuit, V · A |
| Total power series circuit, V · A |
| The gear ratio of pulse telemetry output, imp / kvarh |
| The number of telemetry outputs |
| Weight, not more, kg |
|
Load curve for each quadrant, the number of metering points |
| Digital interface |
| Self-diagnostic system |
| Dimensions, "Energy 8", "STK3-'mm |
| Dimensions, STK1-10 |
| The period of integration |
| Number of seasons |
| The number of time zones for each season |
| Rated voltage U, V |
|
Nominal (maximum) current, A |
1 (1.5), 5 (7.5)
10 (40), 40 (100)
| Number of switching outputs |
| |
The speed of data transmission via RS 485 |
|
Mezhproverochny interval |
| Relative humidity at 30 ° C |
| Atmospheric pressure |
|
|
|
| A100
The counter A100 is designed to account for active energy in single-phase AC circuits in the mode of single-and multi-rate, as well as for use in automated control systems and metering (AMR). Counter A100 distinguish the quality of performance, resistance to temperature changes, high levels of data protection, insensitivity to dc and small size.
- Counter A100 allows you to:
- Implement a one-and dvuhtarifny electricity metering. Switching rates from an external rater.
- Register and store the data confirming the reliability of information, such as:
- The total active energy in the opposite direction.
- A direct indication of the energy flow in the opposite direction on the LCD.
- Number of power failure.
- The total operating time counter.
- Hours after the last power-up.
- The time spent in the counter mode, the lack of current.
- The number of restarts of the microprocessor.
- The number of cases the reverse active energy.
- Transfer data via infrared (IrDA) port or pulse output (RJ11).
- To store data when power is off in non-volatile memory EEPROM.
|
|
| A1000
Counters are used to account for the A1000 active, reactive energy and power measurement in one or two directions in three-phase alternating current circuits, as one and in multirate operation.
A1000 meter allows you to:
- Implement a single and multi-tariff electricity account (up to 4 tariffs). Switching rates from an external rater.
- To carry out measurements in two multirate mode:
- + P - active energy consumption;
- + P,-P - active energy consumed and issued;
- + P, + Q - active and reactive energy;
- +Q, -Q - реактивная потребленная и выданная энергия;
- P = |P1|+ |P2|+ |P3| - активная энергия по модулю;
- P = |P1|+ |P2|+ |P3|, +Q - активная по модулю и реактивная потребленная энергия;
- Фиксировать максимальную мощность.
- Регистрировать энергию при превышении заданного порога мощности нагрузки.
- Регистрировать отсутствие напряжения в одной или двух фазах.
- Измерять и отображать на дисплее пофазно напряжения, токи, активную, реактивную и полную мощности сети.
|
| АЛЬФА Плюс (А2)
Многофункциональные микропроцессорные трех-фазные счетчики электро-энергии АЛЬФА Плюс (А2) предназначен для учета активной и реактивной энергии и мощности в 3-х фазных цепях переменного тока, контроля параметров качества электроэнергии, а также для работы в составе АСКУЭ.
- Измерение активных и реактивных энергий и мощностей в двух направлениях.
- Учет потребленной и выданной энергии в режиме многотарифности.
- Измерение максимальной мощности нагрузки на расчетном интервале времени, фиксация даты и времени максимальной активной и реактивной мощности для каждой тарифной зоны.
- Запись и хранение в памяти счетчика данных графика нагрузки.
- Автоматический контроль нагрузки с возможностью ее отключения или сигнализации.
- Передача результатов измерений по цифровым и импульсным интерфейсам связи (до двух групп гальванически развязанных реле).
Счетчик АЛЬФА Плюс измеряет, вычисляет и отображает на дисплее до 46 величин, относящихся к параметрам электроэнергии. К ним относятся:
- Токи и напряжения фаз.
- Активная, реактивная и полная мощность сети.
- Активная, реактивная и полная мощность фаз.
- Коэффициент мощности cosц сети и каждой фазы.
- Фазные углы векторов напряжений и токов.
- Значение второй гармоники по фазам напряжения.
- Значение второй гармоники по фазам тока.
- Коэффициент искажения синусоидальности напряжения и тока.
- Частота сети.
|
| Дельта
Delta Counter is designed to accommodate active or active-reactive power in three-and single-phase alternating current circuits, as in single-and multirate mode, as well as for use in automated control systems and metering (AMR).
- Measurement of the active-active or reactive energy.
- As one and multirate electricity metering.
- Installing on a DIN-rail or panel.
- Pulse outputs for use in metering.
|

| ST-ER01 (SET)
- Accuracy class: 1.5
- номинальный-максимальный ток, A: 5; 7.5
- nominal frequency of 50 Hz
- Напряжение 3х57.7/100
- полная мощность потребляемая цепью напряжения 1В.А
- operating temperature range, 0C from -25 to +55
- Calibration interval: 6 years
СТ-ЭР02 (СЭТ)
- класс точности: 1.5
- номинальный-максимальный ток, A: 5; 50
- nominal frequency of 50 Hz
- Напряжение 3х380/220
- полная мощность потребляемая цепью напряжения 4.5В.А
- operating temperature range, 0C from -25 to +55
- Calibration interval: 6 years
ST-EA03 (SET)
- Accuracy class: 1
- nominal-maximum current, A: 5, 7.5
- nominal frequency of 50 Hz
- Voltage 3x100
- the total power consumed by the voltage 1V.A
- operating temperature range, 0C from -10 to +55
- Calibration interval: 6 years
ST-EA05 (SET)
- Accuracy class: 1
- nominal-maximum current, A: 5, 7.5
- nominal frequency of 50 Hz
- Voltage 3x100
- the total power consumed by the voltage 1V.A
- operating temperature range, 0C from -10 to +55
- Calibration interval: 6 years
|

|
СО-ЭА05
- Accuracy class: 1.0
- номинальный-максимальный ток, A: 10; 50
- nominal frequency of 50 Hz
- full and active power consumed by the voltage VA 5.5 and 1.3 W, respectively
- диапазон рабочих температур, 0С: от -35 до +55
- Calibration interval: 6 years
|